Even if the stucco on your home has been properly installed and the installation included kick-out flashing for stucco waterproofing water damage can still occur if the stucco is not maintained. Flashing at exterior window and door openings shall extend to the surface of the exterior wall finish or to the water-resistive barrier for subsequent drainage.
Control Joint at Floor Line 2016 Detail.
Kickout flashing stucco. The kick out flashing should slide up under the existing shingles for at least 8 inches. Dormers bays and chimneys are the common locations of damage caused by missing or incorrect kick outs but the kickout flashing should be present and properly installed anywhere a roof and exterior wall intersect. Unfortunately some homeowners dont understand the vital purpose it plays and might remove it because it doesnt look good.
The kickout is installed above the rain gutter andor drip edge flashing where the roof meets a vertical wall. Kick-Out Flashing for Stucco 2019 Detail. The photo above shows a correctly detailed kickout on an EIFS stucco exterior.
This flashing is angled to divert the roof run off water away from the roof and side wall joint point. The image here shows the kickout flashing circled by yellow. In this video i am showing you how to install a piece of kick out flashing for gutters on an eifs sided wall.
Kickout flashings are used where a lower roofline terminates against a vertical wall. It kicks out rain water and diverts it away from the lower wall. Kickout flashing has to be installed over any area where the roof does not completely go over the stucco in order to prevent water from entering between the opening.
Sill Pan for Nail-Flange Windows 2020. First cut and clean the area which needs the fl. Flashing a Nail-Flange Window 2018 rev Detail.
Kickout Flashing is manufactured with powder coating that is compliant with AAMA 2604 standards. With the new flashing in place the water runs down the roof and into the kick out flashing with diverts the water into the gutter instead of just running of the edge of the roof. This kickout is particularly important because it terminates directly at a window openinga fairly common occurrence but one that can be especially devastating.
Top Kickout flashings for stucco Typical details for a kickout flashing at a stucco wall to roof junction. A kick-out flashing can be put in at the time the roof is installed which is the easiest or before the exterior facade is installed or even when performing a roof repair. The kickout is installed above the rain gutter andor drip edge flashing where the roof meets a vertical wall.
A kickout flashing is nothing more than a flashing piece where a roof ends at a vertical wall of the house. Kickout flashings are used where a lower roofline terminates against a vertical wall. We offer a variety of helpful resources at this website.
Kickout flashing plays an integral role in keeping water out by covering joints between your roof and things like walls or chimneys. Wall to RoofDeck Flashing 2020 Detail. The whole premise of the kick-out flashing is to angle or divert the water from the step flashing above and make sure it does not enter behind the facade.
At the intersection of chimneys or other masonry construction with frame or stucco walls with projecting lips on both sides under stucco copings. It kicks out rain water and diverts it away from the lower wall. Walls will eventually have small cracks due to age thus the more water that can be diverted away the less likely it will be for water damage to be a problem.
If the kickout is wrong chances are high that the window flashing is worse and there is little hope of keeping water out of the wall. Kickout flashing can be installed on hardyplank siding stone brick and stucco. Exterior window and door openings.
Kickout flashing may be used for the following. Note that the weather resistant barrierWRB and the metal lath overlap the step and kickout flashings. Weep Screed for Stucco 2020 Detail.
Please visit the American Achitectural Manufacturers Association for more information regarding this rigorous standard. The kickout flashing ensures that water is quickly redirected away or diverted from stucco walls.
Many Problems With Installations Of Lp Smartside Siding Lp Smart Siding Exterior House Siding Shingle Siding
Pin On Home Inspection And Code
Stucco Kickouts Evanston Lp Smart Siding Roof Repair
Rain Water Diverter Flatroofrepairtips How To Install Gutters Roofing Gutters
Pin On Construction Techniques Ideas